Platform · Integrations

Moana connects to the instruments and systems you already run.

Laboratory analysers, imaging modalities, an existing PACS, hospital and partner systems, national reporting platforms and approved applications connect to one Moana record through international standards. Every integration is specified with your team, tested with your own equipment and monitored after go live.

No hospital replaces everything at once. A new platform has to work alongside the analysers, imaging equipment and systems already in service, from the first day.

For hospital ICT teams, laboratory and radiology managers, and ministries of health.

Live message log

What Moana connects to

Six kinds of connection, one patient record.

Each connection uses an international standard rather than a proprietary link, so the hospital is never tied to one vendor and every exchange can be traced.

  • Laboratory analysers and instruments

    MOANA LIS sends orders electronically to the analyser and receives results back for verification before release.

    • ASTM and HL7 v2 analyser interfaces
    • Barcoded sample labels printed at collection
    • Quality control results evaluated against Westgard rules
    • No result reaches the record until a scientist verifies it

    MOANA LIS

  • Imaging modalities

    Requests from the clinician’s order appear on the radiology worklist, and studies return to the patient record as DICOM.

    • DICOM image storage and retrieval
    • Worklists by modality and priority
    • Browser based viewer for clinicians and radiologists
    • Report returned to the requesting clinician

    MOANA PACS

  • An existing hospital PACS

    Moana integrates with the PACS a hospital already runs, so images stay where they are while requests and reports flow through Moana.

    • No migration of the image archive to begin
    • Orders and reports linked to the same patient record
    • MOANA PACS available where a hospital has none

    Radiology

  • Hospital and partner systems

    Patients, orders, results and referrals are exchanged with the systems around the hospital.

    • HL7 v2 messages translated to and from FHIR R4 by the Moana gateway
    • FHIR R4 API for partner hospitals and external diagnostic providers
    • Phased transition alongside an existing hospital system
    • Supply data reconciled with the finance system

    Interoperability

  • National reporting and registries

    National systems are fed from routine care, without separate data entry at the facility.

    • Aggregate indicators reported to DHIS2
    • FHIR bulk export for national data warehouses and research
    • Notifiable conditions coded at the point of care

    National systems

  • Approved applications

    Approved third party applications launch inside Moana with the patient in context.

    • SMART on FHIR app launch
    • Access governed by role and recorded in the audit log
    • The organisation decides which applications are approved

    SMART on FHIR

How an integration is delivered

Specified with your team. Tested with your equipment.

Integrations are delivered as part of implementation, by the Moana team working with the hospital ICT team and, where needed, the instrument vendor. Nothing is connected to live patient care until the department that relies on it has tested it.

  1. 1InventoryEvery instrument and system is listed with the hospital ICT team during scoping: make, model, interface and location.
  2. 2SpecificationMessage types, codes and mappings are agreed, including the test catalogue to LOINC and units to UCUM.
  3. 3ConnectionEach interface is configured on the Moana gateway, working with the instrument vendor where the equipment requires it.
  4. 4Testing with your equipmentReal orders, results and studies run in a test environment and are checked by laboratory and radiology staff before any live use.
  5. 5Go liveThe integration runs alongside the existing process until the department signs off, then becomes the routine path.
  6. 6MonitoringEvery message in and out is logged, and any message that fails is flagged for the ICT team to resolve.

Standards

The standard behind each connection.

StandardUsed for
ASTMOrders and results between MOANA LIS and laboratory analysers
HL7 v2Orders, results and patient information with analysers and existing hospital systems
FHIR R4Record exchange and APIs for partner hospitals, providers and national platforms
SMART on FHIRLaunching approved applications inside Moana with the patient in context
FHIR bulk dataExporting populations for national data warehouses, analytics and research
DICOMStoring, retrieving and viewing medical images, and integrating with an existing PACS
LOINC and UCUMLaboratory tests and units, so a result means the same thing everywhere
ICD 10, ICD 11 and SNOMED CTDiagnoses and clinical findings coded at the point of care
DHIS2Aggregate national indicators reported from routine data

Governance

Integrations you can audit.

  • Every message logged

    Each message in and out is recorded, so integrators can trace exactly what was sent, received and when.

  • Access by role

    Connected systems and applications see only what their role allows, and every access is audited.

  • Verified before release

    Results from instruments are verified by laboratory staff before they reach the clinician.

  • Your data stays yours

    Data exchanged through integrations remains owned by the organisation that collects it.

Questions

What hospitals ask about integration.

Ask about your systems

Can Moana connect to our laboratory analysers?

Yes. MOANA LIS integrates with analysers and instruments that support standard ASTM or HL7 interfaces. Orders are sent to the analyser and results return to the LIS, where a scientist verifies them before release. Each instrument is confirmed during scoping.

Do we need to replace our existing PACS?

No. Moana can integrate with the PACS a hospital already runs. Images stay in the existing archive, while requests, worklists and reports flow through Moana. MOANA PACS is available where a hospital has no PACS.

Can Moana work alongside our current hospital system?

Yes. Through HL7 v2 and FHIR R4, Moana exchanges patient, order and result information with existing systems, either during a phased transition or as a permanent connection with partner systems.

Which analyser and imaging brands are supported?

Moana integrates through open standards rather than brand specific connectors, so what matters for each instrument is whether it supports ASTM, HL7 or DICOM. This is confirmed for every instrument during scoping, before implementation begins.

Who builds and supports the integrations?

The Moana team, working with the hospital ICT team and, where needed, the instrument vendor. Integrations are tested with the hospital’s own equipment before live use and monitored after go live.

Can Moana report to our national health information system?

Yes. Aggregate indicators are reported to DHIS2 from routine data, and FHIR bulk export supports national data warehouses and research.

Send us your list of instruments and systems.

We will map each one to the standard it uses and show your team how it connects to Moana.